Login | Contact | Distributor contact | Imprint
  • Home
  • Search
  • News
  • Downloads
  • Catalogue
  • Register
SHOP ONLINE



  • Applications
  • Products
Proteins, Peptides and Amino acids
  • GFC Analysis
    • Sample Load (KW-803)
    • Effect of Flow Rate (KW-802.5, KW-803)
    • Standard Proteins (1) (KW-802.5)
    • Standard Proteins (2) (KW-802.5 and KW-803)
    • Standard Proteins (14) (KW-802.5)
    • Standard Proteins (15) (KW-803)
    • Standard Proteins (16) (KW-804)
    • Standard Proteins (18) (KW-803)
    • Standard Proteins (19) (KW-804)
    • Standard Proteins (23) (GF-510 HQ)
    • Recovery of Proteins (GF-310 HQ and GS-320 HQ)
    • Recovery of Proteins (GF-510 HQ and GS-520 HQ)
    • Recovery of Proteins (KW-803)
    • Proteins in Human Serum (3) (KW-803)
    • Dimer and Trimer of BSA
    • Crude Albumin (Chicken Egg) (1) (KW-803)
    • Crude Lipoxidase
    • Crude Catalase
    • Crude Hexokinase
    • Human Serum (1) (SB-802 HQ)
    • Effect of Injection Volume of Serum
    • Tryptic Digest of Human IgG
    • Comparison of Chromatograms of Protein mixtures
    • High Sensitive Analysis of Metalloproteins in Rat Liver Cell
    • Human serum
    • Poly-Lysine
    • Glycoprotein Avidi
    • α1 Acid glycoprotein, Orosomucoid
    • Human Control Serum
    • Whey Protein in Yogurt
    • Lectin Protein
    • Peptide Analysis (SEC)
    • Human IgM (2)
    • Avidin (2)
    • Amino Acids (5)
  • Reversed Phased Analysis
    • Effect of Sample Load on Theoretical Plate
    • Standard Proteins (3) (RP18-415)
    • Standard Proteins (4) (C4P-50 4D)
    • Tryptic Digest of Myoglobin (1) (RP18-415)
    • Comparison of Polymer-based Column with Silica-based Column
    • Proteins and Peptides
    • Recovery of Peptides
    • Basic Peptides
    • Effect of Eluent pH (ODP)
    • Analysis of Oligopeptides with Acidic and Alkaline Eluent
    • Comparison of Sample Retention Using ODP, C8P and C4P Columns
    • High Molecular Weight Peptides
    • Oligopeptides (1)
    • Oligopeptides (2)
    • Dipeptides
    • Angiotensins
    • Opioid Peptides (1) (By Post-column Reaction Method)
    • Opioid Peptides (2) (By Pre-column Reaction Method)
    • Tryptic Digest of Myoglobin (2) (ODP-50)
    • Whey Proteins
    • Analysis of Glutathiones (By Post-column Reaction Method)
  • Ion Exchange Analysis
    • Recovery of Proteins and Enzyme Activity (QA-825)
    • Recovery of Proteins and Enzyme Activity (DEAE-825)
    • Recovery of Proteins and Enzyme Activity (SP-825)
    • Recovery of Proteins and Enzyme Activity (CM-825)
    • Effect of Sample Load on Resolution (QA-825)
    • Effect of Sample Load on Peak Width (DEAE-825)
    • Effect of Sample Load on Peak Width (SP-825)
    • Effect of Sample Load on Resolution (CM-825)
    • Effect of pH on Elution Pattern (DEAE-825)
    • Effect of pH on Elution Pattern (SP-825)
    • Standard Proteins (5) (QA-825)
    • Standard Proteins (6) (ES-502N 7C)
    • Standard Proteins (7) (CM-825, SP-825)
    • Standard Proteins (8) (ES-502C 7C)
    • Crude Albumin (Chicken Egg)
    • Human Serum (4) (DEAE-825)
    • Proteins in Human Serum (1) (QA-825)
    • Proteins in Human Serum (2) (DEAE-825)
    • Lipoxidase from Soybean (1) (QA-825, DEAE-825)
    • Lipoxidase (1) (SP-825)
    • Collagen and BSA
    • beta Lactoglobulin Subfractions
    • Angiotensin I, II, III
    • Lysozyme Chloride
    • Trypsin and alpha-Chymotripsin
    • Cytochrome P450 in Rat Liver Microsome
    • Myosin Subfragments
    • Bovine Liver Catalase
    • Purified Kallikrein from Pig Pancreas
    • Ribonuclease A from Equine Pancreas
    • Papain
  • Fast Ion Exchange Analysis
    • Effect of Sample Load on Peak Width (DEAE-420N)
    • Effect of pH on Elution Pattern (DEAE-420N)
    • Standard Proteins (10) (DEAE-825, DEAE-420N)
    • Standard Proteins (20) (SP-420N)
    • Standard Proteins (21) (SP-420N)
    • Fast Analysis of Hexokinase
    • Hemoglobin A, F, S and C
    • Glycosylated Hemoglobin Control I
    • Lipoxidase (3) (DEAE-420N)
    • Urease
    • Human Serum (2) (DEAE-420N)
    • Trypsinogen
    • Lipoxidase (2) (SP-420N)
    • alpha Chymotrypsinogen A
  • Hydrophobic Interaction Analysis
    • Recovery of Proteins and Enzyme Activity (PH-814)
    • Effect of Sample Load on Peak Width(PH-814)
    • Effect of Salt Concentration
    • Standard Proteins (11) (PH-814)
    • Lipoxidase from Soybean (2) (PH-814)
    • Trypsin and Trypsinogen
  • Multimode Analysis
    • Features of Multimode Columns (Peptide Analysis)
    • Calibration Curves for GS-520
    • Standard Proteins (12) (GS-320 7G)
    • Metal Bonded Proteins in Plasma
    • Peptides in Extract from Waste Water Sludge
    • Crude Pronase E
    • Endorphins
    • Chymotrypsin-Hydrolysated Peptides of Ascidian 29K Protein
    • Glutathione in Serum
  • Affinity Chromatography Analysis
    • Albumin, Egg White
    • Antitrypsin
    • Bovine Serum Albumin
    • Standard Proteins (13) (AHR-894)
    • Biotin 4-Aminobenzoic Acid
    • Glutathione S-Transferase
    • Lactate Dehydrogenase
    • Superoxide Dismutase
    • Fibrinogen
    • Plasminogen
    • Human Serum (3) (APG-894)
    • Bovine gamma-Globulin (1) (APR-894)
    • Bovine gamma-Globulin (2) (APA-894)
    • Human gamma-Globulin
    • Human IgM
    • Human Serum Albumin
    • C-Reavtive Protein
    • Trypsin
    • Adenosin Phosphates
    • N-(3,5Dinitrobenzoyl)-DL-Phenyl Glycine
    • Avidin
    • Chymotrypsin
    • Lysozyme (1)
    • Lysozyme (2)
    • Fibronectin
    • Trypsin (Type I)
  • Amino Acid Analysis
    • Amino Acids (2) (NN-814)
    • Amino Acids (3) (P-421S)
    • Carcinogenic Tryptophan Pyrolysis Products
    • Dansyl Amino Acids
    • High Sensitive Analysis of Metal Bonded Amino Acids (1)
    • High Sensitive Analysis of Metal Bonded Amino Acids (2)
    Nucleic Acids
    Saccharides and Organic Acids
    Drugs, Metabolites and Chiral Compounds
    Vitamins, Hormones and Lipids
    Pesticide Residue, Endocrine Disruptors and Environmental Poll
    Synthetic Polymers
    Anions and Cations
    Column Switching
    Other Applications
    NP & RP (Normal & Reversed Phase)
    SEC (Size Exclusion Chromatography)
    Saccharides & Organic Acids Analysis
    IEX (Ion Exchange Chromatography)
    IC (Ion Chromatography)
    HIC (Hydrophobic Interaction Chromatography)
    Affinity Chromatography
    Chiral Separation
    LC/MS & Rapid Analyses of Medicines
    Exclusive Use
    Calibration Standards for SEC
    Column Switching
    GPC Clean-up
    Detectors
    New products
    Download

    Effect of Sample Load on Resolution (QA-825)

    A mixture of transferrin and ovalbumin was injected into IEC QA-825 (a column for ion exchange chromatography) to obtain the relation between sample load and resolution(Rs). With up to 2mg of sample load, the Rs remained at approximately 3 with no decline. Rs was 2.5 when the sample load was 5mg. Even when the sample load was increased to 10 mg, Rs was approximately 2 with satisfactory resolution.


    Sample :
    Transferrin and Ovalbumin

    Column       : Shodex IEC QA-825 (8.0mmID*75mm)
    Eluent       : (A); 20mM Piperazine-HCl buffer(pH6.0)
                   (B); (A) + 0.5M NaCl
                   Linear gradient: 0min to 20min, (A) to (B)
    Flow rate    : 1.0mL/min
    Detector     : UV(280nm)
    Column temp. : Room temp.

     
    © Alle Rechte liegen bei Shodex®