+49 89 9399 6237 info(at)shodex.de Konrad-Zuse-Platz 3, Munich Mo-Thu 8:30 - 17:00 / Fr 8:30 - 16:00
Konrad-Zuse-Platz 3, Munich   

Degassers (Degassers) (Degassers)

 

    Features

    ERC Degassers 3215α, 3415α

    • Remove efficiently dissolved gases in the eluent
    • Pressure sensor and leak monitor assure a high degree of safety
    • Dead volume is minimized to 7 ml/flow channel
    • Any pump can be used since differential pressure is low
    • Continuous degassing mode aids eluent preparation for
      high-sensitivity analysis
    • EMC and LVD compliance, with CE marking

     

    Degassing principle:

    A special synthetic resin membrane (degassing membrane) is used to selectively remove dissolved gasses ; using the charastaristics of the small molecular size of the dissolved gas with high mobility and affinity to the membrane.

     

    Functions, displays:

    • Power On/Off display : "POWER" LED lights, when the power is supplied
    • Status monitoring function : "READY" LED lights, when the internal
      pressure in the vacuum chamber is below a predetermined limit
    • Pressure monitoring function : "PRES" LED lights, when the internal
      pressure in the vacuum chamber does not reach a predetermined level
      within a predetermined time
    • Leak monitor : "LEAK" LED lights, when the liquid leaks in the apparatus
    • Self cleaning : The vacuum line is cleaned by air suction
    • Vacuum pump operation switching function
      NORM. : Controlled operation in normal run
      CONT.: Continuous operation in case of high degree of degassing
    Product Code Product Name Solvent Channels Degassing capacity Internal volume Max. flow rate Dimension, Weight Power source & power consumption Manual
      Y4617004 ERC-3415 α 4 channels When ion-exchanged water saturated with air at 25 ̊C is put through at a flow rate of 3 mL/min, no bubble is observed at the outlet of the apparatus. (Measured dissolved oxygen level at the outlet: 2 ppm at flow rate of 3 mL/min) 7 ml / channel 20mL/min for each channel (Eluent : 25 ̊C Pure water) W71 x D310 x H136 (mm), 5.5 kg AC100V~AC240V, 50/60Hz Please register or
      Y4617000 ERC-3215 α 2 channels When ion-exchanged water saturated with air at 25 ̊C is put through at a flow rate of 3 mL/min, no bubble is observed at the outlet of the apparatus. (Measured dissolved oxygen level at the outlet: 2 ppm at flow rate of 3 mL/min) 7 ml / channel 20mL/min for each channel (Eluent : 25 ̊C Pure water) W71 x D310 x H136 (mm), 5.1 kg AC100V~AC240V, 50/60Hz Please register or