top of page
Shodex GPC KF-800 Series

GPC KD-800 columns

Series with single-pore and mixed-gel columns

GPC columns prefilled with DMF

Product information


GPC KD-800

  • Standard organic solvent SEC (GPC) column

  • Supports a wide range of applications from low to high molecular weight compounds

  • Fulfills USP L21 requirements

  • Prefilled with DMF

  • Available as single-pore and mixed-bed

  • made to order

Mixed gel columns are packed with mixture of gels with different in pore size capable of analyzing samples over a wide range of molecular weight distribution. The mixed gel columns have "M" at the end of the column name.

The guard column is indicated with a "G": GPC KD-G 4A

2-3 columns can be coupled in row.

The solvent can be switchedShodex GPC Columns Solvent Replacement Applicability 2022 (pdf)

Product overview

Product code
Product name
Separation
Functional group
Gel material
Plates per column
Particle size
Pore size
Size (ID x length)
Housing material

Product details

Product name
Maximum pressure
Usual flow rate
Maximum flow rate
Temperature range
Shipping solvent
USP
MW range
Exclusion limit

Product info

Download documents

Operation Manuals:

Operation manuals for each column series can be found on our Japanese website.​

Please click the following link to be directed to the Operation Manual Database. 

https://www.shodex.com/en/download

Applications

Please take a look at the following list of example application data and chromatograms obtained with our columns. These links will redirect you to our Japanese website.

General

Calibration Curves for KD-800 Series (DMF Eluent: PEG, PEO)

Calibration Curves for KD-800 Series (DMF Eluent: PMMA)

Comparison of Calibration Curves for KD-800 Series and SB-800 HQ Series (DMF Eluent)

Comparison of Calibration Curves for KD-802.5 and SB-802.5 HQ (DMF Eluent: PEG, PEO and PS)

Columns

Amino Alcohols (1) (KD-802 + KD-801)

Cellulose (KD-806M)

Cellulose Acetate (1) (KD-806M)

Cellulose Acetate (4) (DMF Eluent: Effects of LiBr Concentration) (KD-806M)

Chlorinated Rubber (KD-806M)

Corn Starch (3) (DMSO/DMF Eluent: KD-806M)

Ethylene Maleic Anhydride Copolymer (Comparison of KD-800 and SB-800 HQ)

Melamine Resin (KD-802)

Melamine-Formaldehyde Resin (DMF Eluent) (KD-802)

N-Vinylpyrrolidone Vinyl Acetate Copolymer (KD-806M)

Phenol Formaldehyde Resin (Comparison of KD-800 and SB-800 HQ)

Phenol Resin (2) (KD-803 + KD-802)

Phenoxy Resin (2) (KD-806M)

Poly(-N,N-Dimethylaminomethyl Styrene) (1) (DMF Eluent) (Comparison KD-800 with SB-800 HQ)

Poly(Ethylene Glycol) Standards (2) (DMF Eluent) (KD-802 + KD-801)

Poly(Ethylene Oxide) Standards (KD-806M + KD-802)

Polycarbonate Resin (2) (Comparison of SB-800 HQ and KD-800)

Polystyrene Standards (9) (KD-802)

Poly(vinylidene Fluoride) (KD-806M)

Polyvinylpyrrolidone (1) (DMF Eluent: KD-806M)

Polyvinylpyrrolidone (4) (DMF Eluent: Effects of LiBr Concentration) (KD-806M)

Potato Starch (DMSO/DMF Eluent: KD-806M)

Styrene Allylalcohol Copolymer (1) (KD-803 + KD-802)

Styrene Acrylonitrile Copolymer (1) (KD-806M)

Styrene Maleic Anhydride Copolymer (KD-806M)

Vinylidene Chloride Acrylonitrile Copolymer (1) (KD-806M)

Vinylidene Chloride Acrylonitrile Copolymer (2) (Comparison of KD-800 and SB-800 HQ)

Vinyl Chloride Vinyl Acetate Copolymer (1) (KD-806M)

Related products

The Shodex STANDARD S-Series is a calibration standard kit for organic size exclusion chromatography.

The Polystyrene (n = 4 to 200,000) is easily soluble in tetrahydrofuran (THF), chloroform, toluene, and o-dichlorobenzene (ODCB).

  • For organic solvent SEC (GPC)

  • Less branched polystyrene with anionic polymerization

STANDARD SL-105 Kit: 10 vials with 0.5 g each (for low MW)

MW 23.000, 13.000, 10.000, 6.500, 4.900, 2.900, 2.000, 1.200, 1.100, 600

 

STANDARD SM-105 Kit: 10 vials with 0.5 g each (for medium MW)

MW 2.330.000, 1.700.000, 740.000, 321.000, 129.000, 57.000, 23.000, 6.500, 2.900, 1.200

STANDARD SH-75 Kit: 7 vials with 0.5 g each (for high MW)

MW 6.550.000, 3.550.000, 3.020.000, 2.330.000, 1.860.000, 885.000, 662.000

The Shodex STANDARD M-75 is Polymethylmethacrylate for SEC, and it is suitable for SEC using hexafluoroisopropanol (HFIP) and dimethylformamide (DMF) solvent. Other usable solvents are tetrahydrofuran (THF), toluene, methyl ethyl ketone, ethyl acetate, DMF, and DMAc.​

  • For organic solvent SEC (GPC)

  • Narrow molecular weight distribution range

Note: Molecular weights (Mp, Mw/Mn) of a standard kit or each single type may vary depending on production lots. Always refer to the inspection certificate.

STANDARD M-75 Kit: 7 vials with 0.5 g each.

PMMA table
bottom of page