IC YS/YK columns
with carboxyl groups
IC columns for cation analysis (suppressor and non-suppressor method)
Product information
IC YS-50
-
High performance type of YK-421
-
Applicable to both suppressor and non-suppressor methods
-
Provides sharp peaks; more significant for divalent cation analysis
-
Supports the analysis of alkylamines and transition metals
-
Fulfills USP-NF L125 requirements
IC YK-421
-
Column for cation analysis with non-suppressor method
-
Simultaneous analysis of monovalent and divalent cations
-
Suitable separating of alkylamines
-
Fulfills USP L76 requirements
Characteristics of IC YS-50
1) Simultaneous analysis of monovalent and divalent cations with isocratic separation.
IC YS-50 enables simultaneous analysis of monovalent and divalent cations at a higher sensitivity than conventional column (IC YK-421). With about twice the theoretical plate number and about 1.3 times the Na+ / NH4+ separatability, the determination performance of NH4+ at a high concentration of Na+ has drastically improved (Na+ : NH4+ = 5,000 : 1 is possible).
2) Quantitative analysis of divalent cations is also improved.
Comparing with conventional column, the theoretical plate number becomes twice. Since peak shapes of divalent cations are improved, so quantitative analysis of divalent cations is also improved.
3) Various acids as the eluent can be used.
Not only methanesulfonic acid but sulforic acid, nitric acid, phospphoric acid, etc. can be used as the eluent.
4) Suitable for analysis of alkylamines.
Analysis of various alkylamines, such as Methylamine and Trimethylamine, is possible.
5) Analysis of transition metals.
With 6 mM Tartaric acid and 4 mM oxalic acid aqueous solution as the eluent, transition metals, such as nickel, zinc, and cobalt can be analyzed.
Product overview
Product code | Product name | Separation | Functional group | Gel material | Plates per column | Particle size | Pore size | Size (ID x length) | Housing material |
---|---|---|---|---|---|---|---|---|---|
F7122000 | IC YS-50 | IC | Carboxyl | Polyvinyl alcohol | ≥ 5,500 | 5 µm | - | 4.6 x 125 mm | steel |
F6700530 | IC YS-G | IC | Carboxyl | Polyvinyl alcohol | (guard) | 5 µm | - | 4.6 x 10 mm | steel |
F7120012 | IC YK-421 | IC | Carboxyl | Silica | ≥ 2,800 | 5 µm | - | 4.6 x 125 mm | steel |
F6709608 | IC YK-G | IC | Carboxyl | Silica | (guard) | 5 µm | - | 4.6 x 10 mm | steel |
Product details
Product name | Maximum pressure | Usual flow rate | Maximum flow rate | Temperature range | pH range | Shipping solvent | USP | Info |
---|---|---|---|---|---|---|---|---|
IC YS-50 | 15 MPa (150 bar) | 1.0 mL/min | 2.0 mL/min | 20 to 60°C | 2 to 12 | 10 mM Na2SO4 aq. | L125 | storage 4-8°C |
IC YS-G | - | - | - | 20 to 60°C | 2 to 12 | 10 mM Na2SO4 aq. | L125 | storage 4-8°C |
IC YK-421 | 15 MPa (150 bar) | - | 1.5 mL/min | 20 to 60°C | - | 5 mM Tartaric acid + 1 mM Dipicolinic acid + 1.5 g/L Boric acid aq. | L76 | storage 4-8°C |
IC YK-G | - | - | - | 20 to 60°C | - | 5 mM Tartaric acid + 1 mM Dipicolinic acid + 1.5 g/L Boric acid aq. | L76 | storage 4-8°C |
Applications
At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.
IC YS-50
Analysis of Tetraalkylammoniums (YS-50)
Analysis of Choline and Acetylcholine (YS-50)
Analysis of Ethanolamines and Alkylamines (YS-50)
Analysis of Ethylamines (YS-50)
Analysis of Imidazole Dipeptide in Processed Meat (YS-50)
Analysis of Ionic Liquid (YS-50)
Analysis of Metabolites from Nitrogen Containing Compounds (YS-50)
Analysis of Methylamines (YS-50)
Analysis of Minerals in Coconut Water (YS-50)
Analysis of Short Chain Alkylamines (YS-50)
Analysis of Trivalent Chromium and Aluminium Ions (YS-50)
Cation Analysis in the Presence of Albumin (YS-50)
Cation Analysis in the Presence of PEG (YS-50)
Cations and Alkylamines (YS-50)
Effects of Crown Ethers (YS-50)
Effects of Flow Rate on Plate Number (YS-50)
Effects of Methanesulfonic Acid Concentration on Elution Time (YS-50)
Effects of Sample Load on Plate Number (YS-50)
Effects of Temperature (YS-50)
Linearity of Calibration Curves (YS-50)
Monovalent and Divalent Cation Standards (6) (Comparison of YS-50 and YK-421)
Monovalent and Divalent Cation Standards (7) (Eluent Containing Acetonitrile) (YS-50)
Monovalent and Divalent Cation Standards (8) (Ethylenediamine Containing Sample) (YS-50)
Monovalent and Divalent Cations Analysis in River Water (Ethylenediamine Containing Sample) (YS-50)
Monovalent and Divalent Cations Analysis in Tap Water (Ethylenediamine Containing Sample) (YS-50)
Transition Metal Ions (3) (YS-50)
IC YK-421
Alkylamines (2) (YK-421) (Phosphoric Acid + Acetonitrile)
Analysis of Amino Alcohols (YK-421)
Analysis of Calcium Acetate Capsules According to USP-NF Method (YK-421)
Analysis of Tap Water (2) (YK-412) (Phosphoric Acid Eluent)
Analysis of Zinc Sulfate Compounded Injection According to USP-NF Method (YK-421)
Dynamic Range of Column (YK-421)
Effects of Acetonitrile Concentration on Elution Volume (YK-421)
Ethanolamines and Alkylamines (YK-421) (Phosphoric Acid + Acetonitrile)
Guidelines for Eluent Selection (YK-421)
High Sensitive Detection of Cations (YK-421)
Long Chain Alkylamines (YK-421)
Monovalent and Divalent Cation Standards (1) (YK-421)
Monovalent and Divalent Cation Standards (2) (YK-421)
Monovalent and Divalent Cation Standards (3) (Dipicolinic Acid + Crown Ether Eluent) (YK-421)
onovalent and Divalent Cation Standards (4) (YK-421) (Phosphoric Acid Eluent)
Monovalent and Divalent Cation Standards (5) (YK-421) (Phosphoric Acid + 18-Crown 6-Ether Eluent)
Monovalent and Divalent Cation Standards (6) (Comparison of YS-50 and YK-421)
Quantification of N-Methylpyrrolidine in Cefepime for Injection According to USP-NF Method (YK-421)