ultra-rapid GPC HK-400 columns
with monodispers particles
Organic size exclusion column for fast analysis
Product information
Monodisperse small particles can obtain low pressure at high flow rate. Therefore the analysis time can be reduced to about one sixth of standard column's analysis time without UHPLC devices. Furthermore, The amount solvent used can be reduced to about a sixth.
-
Newly developed styrene divinylbenzene copolymer monodisperse particles
-
Analysis time is reduced to about a sixth of conventional column's analysis time
-
Low column pressure even under high flow rate does not require a UHPLC system
-
The amount of solvent used is reduced to about a sixth
-
Fulfills USP L21 requirements
Product overview
Product code | Product name | Separation | Gel material | Plates per column | Particle size | Pore size | Size (ID x length) | Housing material |
---|---|---|---|---|---|---|---|---|
F6025010 | GPC HK-401 | GPC | Styrene divinylbenzene copolymer | ≥ 9,000 | 3 µm | 50 Å | 4.6 x 150 mm | steel |
F6025020 | GPC HK-402 | GPC | Styrene divinylbenzene copolymer | ≥ 12,000 | 3 µm | 300 Å | 4.6 x 150 mm | steel |
F6025030 | GPC HK-403 | GPC | Styrene divinylbenzene copolymer | ≥ 9,000 | 3.5 µm | 550 Å | 4.6 x 150 mm | steel |
F6026040 | GPC HK-404L | GPC | Styrene divinylbenzene copolymer | ≥ 9,000 | 3.5 µm | 2,000 Å | 4.6 x 150 mm | steel |
F6025050 | GPC HK-405 | GPC | Styrene divinylbenzene copolymer | ≥ 7,000 | 3 µm | 5,000 Å | 4.6 x 150 mm | steel |
F6025060 | GPC HK-406 | GPC | Styrene divinylbenzene copolymer | ≥ 5,000 | 6.5 µm | 10,000 Å | 4.6 x 150 mm | steel |
F6700200 | GPC HK-G | GPC | - | (guard) | - | - | 1 holder + 1 filter | steel |
F6700100 | GPC HK-G filter | GPC | - | (guard) | - | - | 3 filters | steel |
Product details
Product code | Product name | Maximum pressure | Usual flow rate | Maximum flow rate | Temperature range | Shipping solvent | USP | MW range | Exclusion limit |
---|---|---|---|---|---|---|---|---|---|
F6025010 | GPC HK-401 | 25 MPa (250 bar) | 0.3 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 100 - 1,500 | 2,000 |
F6025020 | GPC HK-402 | 20 MPa (200 bar) | 0.3 to 1.0 mL/min | 1.5 mL/min | ≤ 60°C | THF | L21 | 200 - 10,000 | 20,000 |
F6025030 | GPC HK-403 | 25 MPa (250 bar) | 0.3 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 2,000 - 70,000 | 100,000 |
F6026040 | GPC HK-404L | 25 MPa (250 bar) | 0.3 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 100 - 1,000,000 | 1,000,000 |
F6025050 | GPC HK-405 | 25 MPa (250 bar) | 0.3 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 10,000 - 2,500,000 | 4,000,000 |
F6025060 | GPC HK-406 | 25 MPa (250 bar) | 0.3 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 30,000 - 8,000,000 | 10,000,000 |
F6700200 | GPC HK-G | - | - | - | - | - | - | - | - |
F6700100 | GPC HK-G filter | - | - | - | - | - | - | - | - |
Product info
Product instruction
Applications
At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.
General
Effects of Column Unit on Separation (HK-401: PS)
Effects of Column Unit on Separation (HK-404L: PS)
Effects of Column Unit on Separation (HK-406: PS)
Effects of Flow Rate (1) (HK-404L)
Effects of Flow Rate (2) (HK-404L)
Effects of Flow Rate on Separation (HK-401: PS)
Effects of Flow Rate on Separation (HK-404L: PS)
Effects of Flow Rate on Separation (HK-406: PS)
Calibration Curve for HK-400 series (THF Eluent : PS)
Calibration Curves for HK-400 Series (DMF Eluent: PEG, PEO)
Calibration Curves for HK-400 Series (HFIP Eluent : PMMA)
Effects of Flow Rate on the Column Pressure (HK-400 series)
Applications
Absolute Molecular Weight Determination of Star-shaped Polystyrene (HK-404L)
Biodegradable Polymer (4) (Polylactic Acid) (HK-404L)
Comparison of HK-404L and KF-805L
Comparison of Separation using HK-404L with Conventional Device and Semi-micro Type Device (HK-404L)
Epoxy Resin (4) (Comparison of HK-404L and HK-404L + HK-401)
Epoxy Resin (5) (Comparison of HK and KF-800 Series Columns)
Epoxy Resin (6) (Comparison of HK-402 and KF-802.5)
Epoxy Resin (7) ( Effects of Flow Rate for HK-402)
Poly(4-vinylpyridine) (HK-404L)
Poly(Butyl Methacrylate) (2) (HK-404L)
Poly(Methyl Methacrylate) (3) (HK-404L)
Polyamide (12) Nylon 6/9 (HK-404L)
Polyamide (13) Nylon 11 (HK-404L)
Polyamide (14) Nylon 12 (HK-404L)
Polyamide (15) Nylon 6/10 (HK-404L)
Polyamide (16) Nylon 6/6 (HK-404L)
Polyamide (17) Nylon 6/12 (HK-404L)
Polyamide (18) Nylon 6(3)T (HK-404L)
Polystyrene Standards (23) (HK-404L)
Polystyrene Standards (24) (HK-401)
Polystyrene Standards (25) (HK-402)
Related products
The Shodex STANDARD S-Series is a calibration standard kit for organic size exclusion chromatography.
The Polystyrene (n = 4 to 200,000) is easily soluble in tetrahydrofuran (THF), chloroform, toluene, and o-dichlorobenzene (ODCB).
-
For organic solvent SEC (GPC)
-
Less branched polystyrene with anionic polymerization
STANDARD SL-105 Kit: 10 vials with 0.5 g each (for low MW)
MW 23.000, 13.000, 10.000, 6.500, 4.900, 2.900, 2.000, 1.200, 1.100, 600
STANDARD SM-105 Kit: 10 vials with 0.5 g each (for medium MW)
MW 2.330.000, 1.700.000, 740.000, 321.000, 129.000, 57.000, 23.000, 6.500, 2.900, 1.200
STANDARD SH-75 Kit: 7 vials with 0.5 g each (for high MW)
MW 6.550.000, 3.550.000, 3.020.000, 2.330.000, 1.860.000, 885.000, 662.000
The Shodex STANDARD M-75 is Polymethylmethacrylate for SEC, and it is suitable for SEC using hexafluoroisopropanol (HFIP) and dimethylformamide (DMF) solvent. Other usable solvents are tetrahydrofuran (THF), toluene, methyl ethyl ketone, ethyl acetate, DMF, and DMAc.
-
For organic solvent SEC (GPC)
-
Narrow molecular weight distribution range
Note: Molecular weights (Mp, Mw/Mn) of a standard kit or each single type may vary depending on production lots. Always refer to the inspection certificate.
STANDARD M-75 Kit: 7 vials with 0.5 g each.